Key Points Mobitz I is usually due to an AV nodal problem and responds well to atropine when needed, permanent pacemaker placement is not indicated Mobitz I blocks are characterized…
Key Points Patients with Mobitz II or high grade 2nd degree AV blocks usually need permanent pacemaker placement Mobitz II blocks are characterized by a sudden failure of conduction after…
Key Points 2:1 Conduction Overview: This specific type of 2nd degree AV block is characterized by every other P wave being non-conducted, leading to a 2:1 conduction pattern. Diagnostic Challenge:…